CS dewpoint sensor DP 300

Tuesday, 01 March 2011 08:18
Inquiry
Download attachments:
CS dewpoint sensor DP 300

Keeping a specific dew point is the requirement for a troublefree plant operation. The mobile dew point measuring instrument  DP 300 is the ideal service instrument in a handy case.

It measures the dew point, relative humidity and temperature up to 50 bar, easy, fast, without an annoying cable.

With the PC software the measured data can be recorded in an Excel file and further parameters can be selected: ppm, g/kg, mg/m³ , atmospheric dew point.

 

Features:

  • Easy to use portbale dew point meter
  • Fast and reliable measurement of compressed air and gases
  • Practical connection to air/gas medium through measurement chamber and quick connector
  • Clear display
 

Technical Data:

Technical data DP 300
Display single linedewpoint (ºCtd resp. ºF)
relative humidity ( %RH)
temperature (ºC resp. ºF)
alternatively to the dewpoint further parameters can be displayed: ppmV/V, atmospheric dewpoint in ºC, g/m3, mg/m3, g/kg and ºF
Display functionsMax, Min, state of battery
Measuring range-80 to 20 ºCtd
-20 to 70 ºC
0 up to 100 %RH
Pressure range-1 up to 1.5 MPa standard
-1 up to 35 MPa high pressure version
Accuracytypical ± 2 ºCtd at -40 ºCtd
Power supplyInternal chargeable storage battery (NiMh)
for approx.  15 h continual operation
continual measurement with mains operation via recharger
display low batt max. 2 hours remaining operating
time
Operating temperature0 to 50 ºC
EMCDIN EN 61326
Screw-in threadG 1/2" stainless steel
HousingPolycarbonate
Charger
Input 100...240 VAC / 0.2A, 50-60 Hz
Output 24 VDC / 300mA
Transport temperature-20 ... +50 ºC 
 

Application:

N/A
 

Order. No:

Order No.Description
0600 6001Pro DP 300 Set consisting of:
0560 6000DP 300 instrument
0699 3492Measuring chamber for mobile application
0554 0003Teflon hose with fast connection
0554 0001Battery charger for DP 300 
0554 6002Hard case for DP 300

Additional accessories not included in the set:
0699 3396Dewpoint calibration at 3 points between -70...+20 ºCtd
0699 3690Measuring chamber for atmospheric pressure dewpoint
0699 3493By-pass-type chamber with 6 mm hose in and out connection up to 1.5 MPa
0554 0002Checking pot at 11.3% RH
 
Last modified on Friday, 18 November 2011 02:32